Root Canal Instruments Dental Endodontic Niti Rotary Super Files Universe Engine , Use for Dental Root Canal Treatment in Cutting Dentin.
Specifications:
Taper | SX | .05 |
S1 | .03 |
S2 | .04 |
F1 | .07 |
F2 | .08 |
F3 | .09 |
F4 | .06 |
F5 | .05 |
Torque | SX | 3.0 N/CM |
S1 | 3.0 N/CM |
S2 | 1.0 N/CM |
F1 | 1.5 N/CM |
F2 | 2.0 N/CM |
F3 | 2.0 N/CM |
F4 | 2.0 N/CM |
F5 | 2.0 N/CM |
Rotary Speed Range | SX | 325-375 RMP |
S1 | 325-375 RMP |
S2 | 325-375 RMP |
F1 | 325-375 RMP |
F2 | 325-375 RMP |
F3 | 325-375 RMP |
F4 | 325-375 RMP |
F5 | 325-375 RMP |
Size | SX | #19 |
S1 | #18 |
S2 | #20 |
F1 | #20 |
F2 | #25 |
F3 | #30 |
F4 | #40 |
F5 | #50 |
ISO Color | SX | Yellow |
S1 | Violent |
S2 | White |
F1 | Yellow |
F2 | Red |
F3 | Blue |
F4 | Yellow |
F5 | Red |
Using Times | SX | 8-10 times |
S1 | 10-12 times |
S2 | 10-12 times |
F1 | 8-10 times |
F2 | 12-15 times |
F3 | 12-15 times |
F4 | 12-15 times |
F5 | 12-15 times |
Cross Section | Triangle |
Description:
Dental universal engine root canal niti rotary super files is the multiple tapered instrument. With continuous multi-taper design, each file has its own specific work area. Super Files make canal shaping easier, safer, faster, and more efficient.
Structure
The system is comprised of three shaping files(SX,S1,S2) and three finishing files(F1,F2,F3).
1. Shaping Files(SX,S1,S2):Using SX to make the formation of crown and short root canal, preparing the upper 1/3 root canal with S1, S2 for middle 1/3 root canal preparation.
2. Finishing Files〈F1,F2,F3〉:All used for the formation of 1/3 root canal tip.
Operation Sequence:
1. Establishing linear channel , cleaning the canal with sodium hypochlorite
2. Detect the root canal Using #10, #15 SSK file
3. Makes the formation of crown with SX and create the canal path (cleaning with Sodium Hypochlorite )
4. Preparation the upper 1/3 crown with S1 , flush canal with sodium hypochlorite solution (STDN ) after getting it out
5. Using the same rotary method to the working length with S2 , and flush canal with sodium hypochlorite solution (STDN )
6. Using F1 to the working length , which could make a smooth connect between the 1/3 canal tip and middle 1/3 canal
7. F2 to the working length and using #25 K files to measure the diameter of apical foramina , which indicating finished the preparation and it could be filled if it is loose
8. Using the F3 to the working length if you didn't feel loose when using the #25 K files.
Warning:
1.Only skilled dentists are allowed to use.
2. Be sure to sterilize this product for each use.
3. Do not use this product except for the dental service and treatment. Use it in accordance with the intended use.
<Precautions for use>
1. To prevent infection, sterilize the product by autoclave and make sure
sterilization is completed before using.
2. Choose the most appropriate type for each case and follow the general
method.
3. Before using, make sure the instruments outside of dental cavity that
there are no deformations, scratches and cracks.
4. If the head of product is thin, long or large, there are possibilities for
breaking or twisting. Because of this, be sure to avoid using
unreasonable angle and excessive pressure.
5. Wear safety glasses to protect your eyes from damage. Also, wear a
dust protective mask to prevent inhaling dust.
6. Wear rubber dam etc. to avoid accidental ingestion and falling.
7. Do not use this instrument for any purposes except for listed
applications above.
8. Only for use by dentists.
9. After using, follow an appropriate treatment as medical waste.
10. Dispose the product if damaged or contaminated.
11. After using, wash it with medical cleaning agent and brush, then
wash away foreign substances like adherent body fluids and body
tissues.
12. Set the product to a stand when cleaned by ultrasonic cleaner to avoid
working part deterioration.
13. Use this product with great care to avoid puncturing fingers because
of its possession of sharp-edged part.
<Storages and duration of use>
1. Avoid storing at high temperature, humidity and direct sunlight.
Keep liquids away. Store it at room temperature.
2. Do not damage or make a pinhole to packaging materials.
3. Do not keep under germicidal lamp to avoid deterioration.
<Maintenances and inspections>
1. Sterilize this product by autoclave under established method and
term for each use.
Method of sterilization:
Put this product in a sterilization pack or (or foil) and place it on a
sterilization tray, or files stand for autoclave sterilization with
reference to the following terms.
Terms for sterilization:
term(1) temperature: 121degrees Celsius time: 20 minutes or more
term(2) temperature: 126degrees Celsius time: 15 minutes or more
2. Do not use high pressure steam sterilizer which heats more than 200
degrees Celsius including drying process.
3. When reusing the instrument, wash away foreign substances
completely and sterilize.
4. Regarding use of medical cleaning agent, follow the instruction
manual by its manufacturer strictly.
5. Dispose the product if damaged or decreased in performance
Legal Manufacturer
SHENZHEN FEIHUAN MEDICAL INSTRUMENTS CO., LTD
Add:1305 Wensheng Center, Wenjin Plaza, 1st road Tianbei, Luohu District, Shenzhen. China, 518000
Tel:+86-755-28540953 Fax:+86-755-28540953
EU Representative
SUNGO Europe B.V.
Olympisch Stadion 24, 1076DE Amsterdam, Netherlands
Applications:
Dental Root Canal Treatment | Hospital , Clinic , lab... |
Competitive Advantage:
Root canal preparation is one of the most important factor in RCT. Flexibility and shape memory of NiTi instrument, to improve preparation efficiency and reduce fatigue.
To know NiTi feature and cross section design well ,which can get a better understanding about instrument performance and do the best choice.